FOR USE WITH LANDSCAPE LIGHTING SYSTEMS ONLY.
1) The device is accepted as a component of a landscape lighting system
where the suitability of the CSA or UL labeled combination shall be deter
mined by CSA, UL respectively or the local inspection authorities having
jurisdiction.
2) Fixture shall be connected to an extra low voltage transformer approved
for use with landscape lighting systems.
3) Thisxtureistobeconnectedtoasecondarywiringofthefollowingtype:
12 GA 60°C minimum type;
SPT-3 suitable for outdoor use; or
approved landscape lighting cable.
ASSEMBLY AND INSTALLATION
1) Determinedesiredlocationformountingxture.
2) Usingg.A,markpositionfordrililngpilotholesandforwirewayhole(if
desired).
NOTE: Fig. A is drawn actual size, it can be used as a template or be used
as a template or be referenced for dimensions.
3) Drill3/32”(2mm)pilotholesinmountingsurfaceatpositionsmarked.If
usingawirewayholealsodrillthatatthistime.Suggestedsize1/4”(6mm).
4) Assemblemountingbrackettomountingsurfaceusingprovidedscrews.
5) Carefullyslipporcelainshadeovermountingbracket.Holeinbackof
shadeshouldtsnugbetweenmountingsurfaceanddimpleonbackside
of tab.
NOTE::Ifshadedoesnotseemsnugenoughorseemstoosnug,adjust
by slightly bending tab in or out.
6) TURN OFF POWER. Disconnect or unplug transformer.
7) MakewireconnectionsusingsuppliedQuicDisc
™
following instructions
below,orusingotherapprovedwiringconnectionmethod(notsupplied.)
Date Issued: 11/25/11 IS-15065-CB
DOM ETRE INSTALLE A L’EXTERIEUR
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
For warranty information please visit: http://www.landscapelighting.com/portal/warranty_page
Pour de plus amples informations sur la garantie, cliquez sur le lien ci-dessous : http://www.landscapelighting.com/portal/warranty_page
QUIC DISC
™
WIRING INSTRUCTIONS
Turn off power.
Thefulllengthofthe18GAxturewiremaybeusedtoconnectwiththe10GAor12GAcableprovidedthefollowingconditionsaremet:
•Wiringistobeprotectedbyroutingclosetothextureoraccessoryorsecuredtoabuildingstructuresuchashouseordeck.
• 18GAxturewiringistobecutoffsothatitisattachedtotheconnectorwithin6inchesofthextureorbuildingstructure.
• Ifitisnecessarytomaketheconnectionsunderground,thennomorethan6inchesofthe18GAxturewireistobeburied.
TheQuicDisc
™
connector is designed to install onextureandaccommodatesone18GAxturewireandone 10 GA or one 12 GA supply wire.
Placethe10gaugesupplywireacrosstheareamarked10GAonQuicDisc
™
orplacethe12gaugesupplywireacrosstheareamarked12GA
onQuicDisc
™
.
Placethe18gaugexturewireacrosstheareamarked18GAontheQuicDisc
™
.Afterthewiresareinplace,connectathetopoftheQuic
Disc
™
tothebasewithsuppliedscrew,makingsurethatthewiresremainatinthebottomportionoftheQuicDisc
™
, and the screw is tightened
all the way down.
Thecoppercontactswillautomaticallypiercethewires’insulation.Excess18GAxturewirethatsticksouttheendoftheQuicDisc
™
is to be cut off.
Makenootherwiringconnectionstothe18GAxturewire.
3/8
7/16
1-1/16
WIREWAYHOLE
GUIDE-FIL
PILOTHOLES
AVANT-TROUS
SCREWS
VIS
DIMPLE
CRAN
TAB
PATTE
MOUNTINGBRACKET
SUPPORTDEFIXATION
FIG.A
SHADE
ABAT-JOUR